Jlg 10MSP Operator Manual Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
SECTION 3 - MACHINE OPERATION
3121227 – JLG Lift – 3-15
Table 3-2. LCD Display - Operating Fault Conditions
FAULT
CODE
PLATFORM
LEDs
FLASHING
LCD SYMBOL SCREEN LCD TEXT SCREEN
FAULT DESCRIPTION/
MACHINE CONDITION
TO CORRECT PROBLEM
——
Brakes Released -
(DRIVE Disabled)
To Engage Brakes - Press Brake
Release Button on Ground Control
Station
——
Charger AC Plugged In DRIVE Dis-
abled
Unplug Charger AC Power Cord
——
Programmable Security Lock
Password
Enter Code on PSL Keypad to
Power-Up Machine
—3
Low Battery -
(Warning Level 1)
Charge Batteries to Four (4) Bars or
more on Indicator.
—2
Charge Battery - (LIFT UP Dis-
abled) (Warning Level 2)
Charge Batteries a Minimum of
Four (4) Hours or eight (8) LEDs/
BARS lit.
—1
Charge Battery - (LIFT UP/DRIVE
Disabled) (Warning Level 3)
Charge Batteries a Minimum of
Four (4) Hours or eight (8) LEDs/
BARS lit.
43
Tilt Condition (Platform Elevated)
DRIVE and Lift UP Disabled
Lower the Platform and Drive off
the Tilt Condition
00000.0
00000.0
00000.0
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 95 96

Comentarios a estos manuales

Sin comentarios