Section 2 - Pre-Operation and Controls
2-11
31200029
9. System Distress Indicator:
a. Flashes yellow and buzzer sounds intermittently when pressure is low in
either outrigger.
b. Illuminates yellow and buzzer sounds when one of the following items is out
of range.
Engine Oil Pressure
Engine Temperature
Transmission Temperature
•Air Filter
Hydraulic Oil Filter
CAN Bus
Engine Speed Sensor
Hydraulic Pump Pressure
Short Circuit Main Control Valve
Boom Angle Sensor
c. Illuminates for three seconds then flashes for three seconds when
conditions a and b occur simultaneously.
10. Platform Overload
: Illuminates red and buzzer sounds when platform capacity is
exceeded. All functions are inoperable until load is decreased.
CAUTION
EQUIPMENT DAMAGE. When a red light or the system distress indicator
illuminates and a warning tone is heard, immediately lower platform to ground
and stop engine. Determine cause before continued use.